Analog Integrated Circuit Device Data
6
Freescale Semiconductor
33989
ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 3. Static Electrical Characteristics
Characteristics noted under conditions 5.5 V
VSUP 18 V, -40 C TA 125 C, GND = 0 V, unless otherwise noted.
Typical values noted reflect the approximate parameter means at TA = 25 °C under nominal conditions, unless otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER INPUT (VSUP)
Nominal DC Supply Voltage Range
VSUP
5.5
—
18
V
Extended DC Voltage Range 1
Reduced Functionality
(8)VSUPEX1
4.5
—
5.5
V
Extended DC Voltage Range 2
(9)VSUPEX2
18
—
27
V
Input Voltage During Load Dump
Load Dump Situation
VSUPLD
—
40
V
Input Voltage During Jump Start
Jump Start Situation
VSUPJS
—
27
V
IOUT at VDD1 = 40 mA CAN recessive or Sleep-Disable State
ISUP(STDBY)
—
42
45
mA
Supply Current in Normal Mode
(10)IOUT at VDD1 = 40 mA CAN recessive or Sleep-Disable State
ISUP(NORM)
—
42.5
45
mA
VDD1 and V2 OFF, VSUP < 12 V, Oscillator Running (12) CAN in Sleep-Disable State
ISUP(SLEEP1)
—
72
105
A
VDD1 and V2 OFF, VSUP < 12 V, Oscillator Not Running (12) CAN in Sleep-Disable State
ISUP(SLEEP2)
—
57
90
A
VDD1 and V2 OFF, VSUP > 12 V, Oscillator Running (12) CAN in Sleep-Disable State
ISUP(SLEEP3)
—
100
150
A
Supply Current in Stop Mode IOUT VDD1 < 2.0 mA
VDD1 ON, VSUP < 12 V, Oscillator Running (12) CAN in Sleep-Disable State
ISUP(STOP1)
—
135
210
A
Supply Current in Stop Mode IOUT VDD1 < 2.0 mA
VDD1 ON, VSUP < 12 V, Oscillator Not Running (12) CAN in Sleep-Disable State
ISUP(STOP2)
—
130
210
A
Supply Current in Stop Mode IOUT VDD1 < 2.0 mA (10) (11) VDD1 ON, VSUP > 12 V, Oscillator Running (12) CAN in Sleep-Disable State
ISUP(STOP3)
—
160
230
A
BATFAIL Flag Internal Threshold
VBF
1.5
3.0
4.0
V
Notes
8.
VDD1 > 4.0 V, Reset high, logic pin high level reduced, device is functional.
9.
Device is fully functional. All functions are operating. All modes available and operating. Watchdog, HS1 turn ON turn OFF, CAN cell
operating, L0:L3 inputs operating, SPI read/write operation. Overtemperature may occur.
10.
Current measured at the VSUP pin.
11.
With CAN cell in Sleep-Disable state. If CAN cell is Sleep-Enabled for wake-up, an additional 60 A must be added to specified value.
12.