XRT86VL38
129
OCTAL T1/E1/J1 FRAMER/LIU COMBO - E1 REGISTER DESCRIPTION
REV. V1.2.1
T
ABLE
107: R
ECEIVE
SA I
NTERRUPT
S
TATUS
R
EGISTER
(RSAISR) H
EX
A
DDRESS
: 0
X
nB0C
B
IT
F
UNCTION
T
YPE
D
EFAULT
D
ESCRIPTION
-O
PERATION
7
SA6_1111
RUR/
WC
0
Change in Debounced Sa6 = 1111 Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Debounced Sa6=1111” interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1.
Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1111 pattern.
2.
Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1111 pattern.
0 = Indicates that the “Change in Debounced Sa6=1111” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Debounced Sa6=1111” interrupt
has occurred since the last read of this register
6
SA6_1110
RUR/
WC
0
Change in Debounced Sa6 = 1110 Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Debounced Sa6=1110” interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1.
Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1110 pattern.
2.
Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1110 pattern.
0 = Indicates that the “Change in Debounced Sa6=1110” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Debounced Sa6=1110” interrupt
has occurred since the last read of this register
5
SA6_1100
RUR/
WC
0
Change in Debounced Sa6 = 1100 Interrupt Status
This Reset-Upon-Read bit field indicates whether or not the
“Change in Debounced Sa6=1100” interrupt has occurred since the
last read of this register.
If this interrupt is enabled, then the Receive E1 Framer block will
generate an interrupt in response to either one of the following
conditions.
1.
Whenever the Receive E1 Framer block detects the
Debounced Sa6 equals to the 1100 pattern.
2.
Whenever the Receive E1 Framer block no longer detects the
Debounced Sa6 equals to the 1100 pattern.
0 = Indicates that the “Change in Debounced Sa6=1100” interrupt
has not occurred since the last read of this register
1 = Indicates that the “Change in Debounced Sa6=1100” interrupt
has occurred since the last read of this register