44
MON08 Multilink User Manual
P&E
Microcomputer
Systems, Inc.
MON08 MULTILINK
The device type selection box allows the user to specify what type of HC08
they are communicating with. The dialog will then display the appropriate
pinout to be implemented on the MON08 connector, so that the P&E interface
can talk to it properly. The values given (1 or 0) are for informational purposes
only and are driven by the P&E interface.
Device Power
Figure 4-42: Device Power Dialog
The device power selection allows the user to specify whether the target is 2, 3,
or 5 Volts, and whether this power is switched/generated by the P&E interface
or if it is separately supplied to the target and under user control. If it is under
user control, the software will use dialog boxes to ask the user to power the
target up and down when necessary (similar to Class II-IV).
Device Clock
Figure 4-43: Device Clock Selection Box
The device clock menu allows three options:
1) P&E provides clock to target
2) The target has its own clock (1-32MHz)
3) The target has a slow crystal (30KHz-100KHz) with PLL circuitry. P&E
tries to enable the PLL to allow programming and debug at higher speeds.
Baud
There is no need to set baud rate for Class V, VI, or VII targets, as it is auto-
detected from the target.
4.3.1.3
Advanced Settings Dialog
The Advanced Button brings up a dialog which allows the user to set specific
protocol settings. The following is an explanation of each part of the advanced