Check SBI0SR2<AL>, SBI0SR2<TRX>, SBI0SR2<AAS> and SBI0SR2<AD0> and implement process-
Table 18-5 Operation in the Slave Mode
SBI0SR2<
TRX>
SBI0SR2<
AL>
SBI0SR2<
AAS>
SBI0SR2<
AD0>
Conditions
Process
1
0
The serial bus interface circuit loses arbi-
tration when transmitting a slave address,
and receives a slave address of which the
value of the direction bit sent from another
master is "1".
Set the number of bits in 1 word to
SBI0CR1<BC> and write the transmitted
data to the SBI0DBR.
0
1
0
In the slave receiver mode, the serial bus
interface circuit receives a slave address
of which the value of the direction bit sent
from the master is "1".
0
In the slave transmitter mode, the serial
bus interface circuit finishes the transmis-
sion of 1-word data
Check SBI0SR2<LRB>. If it is set to "1", set
SBI0CR2<PIN> to "1" since the receiver
does not request subsequent data. Then,
clear SBI0CR2<TRX> to "0" to release the
bus. If SBI0SR2<LRB> is set to "0", set the
number of bits in 1 word to SBI0CR1<BC>
and write the transmitted data to SBI0DBR
since the receiver requests subsequent da-
ta.
0
1
1/0
The serial bus interface circuit loses arbi-
tration when transmitting a slave address,
and receives a slave address of which the
value of the direction bit sent from another
master is "0" or receives a "GENERAL
CALL".
Write the dummy data (0x00) to the
SBI0DBR to set SBI0CR2<PIN> to "1", or
write "1" to SBI0CR2<PIN>.
0
The serial bus interface circuit loses arbi-
tration when transmitting a slave address
or data, and terminates transferring the
word data.
The serial bus interface circuit is changed
to the slave mode. Write the dummy data
(0x00) to the SBI0DBR to clear
SBI0SR2<AL> to "0" and set
SBI0CR2<PIN> to "1".
0
1
1/0
In the slave receiver mode, the serial bus
interface circuit receives a slave address
of which the value of the direction bit sent
from the master is "0" or receives "GEN-
ERAL CALL".
Write the dummy data (0x00) to the
SBI0DBR to set SBI0CR2<PIN> to "1", or
write "1" to SBI0CR2<PIN>.
0
1/0
In the slave receiver mode, the serial bus
interface circuit terminates the receipt of
1-word data.
Set the number of bits in 1-word to
SBI0CR1<BC>, read the received data
from the SBI0DBR and write the dummy
data (0x00).
Note:In the slave mode, if the slave address set in I2C0AR<SA> is "0x00", a START Byte "0x01" in I2C bus standard
is received, the device detects slave address match and SBI0CR2<TRX> is set to "1". Do not set I2C0AR<SA>
to "0x00".
18.5.4
Stop condition generation
When SBI0CR2<BB> is "1", a sequence of generating a stop condition is started by setting "1" to
SBI0CR2<MST>, SBI0CR2<TRX> and SBI0CR2<PIN> and clearing SBI0CR2<BB> to "0". Do not modify
the contents of SBI0CR2<MST>, SBI0CR2<TRX>, SBI0CR2<BB> and SBI0CR2<PIN> until a stop condition
is generated on a bus.
When a SCL line on a bus is pulled down by other devices, a serial bus interface circuit generates a stop
condition after a SCL line is released.
The time from the releasing SCL line until the generating the STOP condition takes tHIGH.
TMP89FH42
18. Serial Bus Interface (SBI)
18.5 Data Transfer of I2C Bus
Page 296
RA002