TWO CHANNEL INTEGRATED UART AND RS-485 TRANSCEIVER
2.11.1
Receive Holding Register (RHR) - Read-Only
The Receive Holding Register is an 8-bit register that holds a receive data byte from the Receive Shift
Register. It provides the receive data interface to the host processor. The RHR register is part of the receive
FIFO of 64 bytes by 11-bits wide, the 3 extra bits are for the 3 error tags to be reported in LSR register. When
the FIFO is enabled by FCR bit-0, the RHR contains the first data character received by the FIFO. After the
RHR is read, the next character byte is loaded into the RHR and the errors associated with the current data
byte are immediately updated in the LSR bits 2-4.
2.11.2
Selectable Input to RX of Channel B
There is an input (RXBSEL) that selects whether the signal going to the RXB input of the UART will be the
signal from the RS-485 transceiver or not. If RXBSEL is LOW, then the signal to the RXB input is the RXB+
and RXB- signals from the RS-485 transceiver. When RXB+ and RXB- are used, the RXB input should be left
floating. The signal received at the UART can be probed at the RXB pin. If RXBSEL is HIGH, then the RXB+
and RXB- pins are tri-stated and RXB can be used with an external Infrared transceiver or RS-232 transceiver.
If RXB is selected but is unused, RXB should be connected to VCC. See Figure 7 for a detailed drawing.
FIGURE 10. RECEIVER OPERATION IN NON-FIFO MODE
Receive Data Shift
Register (RSR)
Receive
Data Byte
and Errors
RHR Interrupt (ISR bit-2)
Receive Data
Holding Register
(RHR)
RXFIFO1
16X or 8X Clock
(EM SR bit-7)
Receive Data Characters
Data Bit
Validation
Error
Tags in
LSR bits
4:2
2.12
Auto Xon/Xoff (Software) Flow Control
When software flow control is enabled (See Table 15), the L402 compares one or two sequential receive data
characters with the programmed Xon or Xoff-1,2 character value(s). If receive character(s) (RX) match the
programmed values, the L402 will halt transmission (TX) as soon as the current character has completed
transmission. When a match occurs, the Xoff (if enabled via IER bit-5) flag will be set and the interrupt output
pin will be activated. Following a suspension due to a match of the Xoff character, the L402 will monitor the
receive data stream for a match to the Xon-1,2 character. If a match is found, the L402 will resume operation
and clear the flags (ISR bit-4).
Reset initially sets the contents of the Xon/Xoff 8-bit flow control registers to a logic 0. Following reset the user
can write any Xon/Xoff value desired for software flow control. Different conditions can be set to detect Xon/
Xoff characters (See Table 15) and suspend/resume transmissions. When double 8-bit Xon/Xoff characters
are selected, the L402 compares two consecutive receive characters with two software flow control 8-bit
values (Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions accordingly. Under the above described flow
control mechanisms, flow control characters are not placed (stacked) in the user accessible RX data buffer or
FIFO.
In the event that the receive buffer is overfilling and flow control needs to be executed, the L402 automatically
sends an Xoff message (when enabled) via the serial TX output to the remote modem. The L402 sends the
Xoff-1,2 characters two-character-times (= time taken to send two characters at the programmed baud rate)
after the receive FIFO crosses the programmed trigger level (for all trigger tables A-D). To clear this condition,
the L402 will transmit the programmed Xon-1,2 characters as soon as receive FIFO is less than one trigger
level below the programmed trigger level (for Trigger Tables A, B, and C) or when receive FIFO is less than the
相關PDF資料
PDF描述
W681511DK KIT DEVELOPMENT FOR W681511
M3DDK-1420K IDC CABLE - MKR14K/MC14F/MKR14K
5503162-5 CABLE ASSY,2.5BAY,SM DUAL,5 M1
ACC06DRXS CONN EDGECARD 12POS .100 DIP SLD
RBC17DREI-S13 CONN EDGECARD 34POS .100 EXTEND
相關代理商/技術參數(shù)
參數(shù)描述
XR19L402IL48-F 功能描述:UART 接口集成電路 UART RoHS:否 制造商:Texas Instruments 通道數(shù)量:2 數(shù)據(jù)速率:3 Mbps 電源電壓-最大:3.6 V 電源電壓-最小:2.7 V 電源電流:20 mA 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 封裝 / 箱體:LQFP-48 封裝:Reel
XR1AEX2NV1XX 制造商:Eaton Corporation 功能描述:SWITCH, ROCKER, SPST, 18A, 125VAC, BLACK, Contact Configuration:SPST, Switch Ope 制造商:Eaton Corporation 功能描述:SWITCH, ROCKER, SPST, 18A, 125VAC, BLACK, Contact Configuration:SPST, Switch Operation:Off-On, Contact Current Max:18A, Contact Voltage AC Nom:125V, Switch Mounting:Panel, Actuator / Cap Color:Red, Illumination Color:Red , RoHS Compliant: Yes
XR1AEX3NV1XX 制造商:Eaton Corporation 功能描述:SWITCH, ROCKER, SPST, 18A, 125VAC, BLACK, Contact Configuration:SPST, Switch Ope
XR1AEX4NV1XX 制造商:Eaton Corporation 功能描述:SWITCH, ROCKER, SPST, 18A, 125VAC, BLACK, Contact Configuration:SPST, Switch Operation:Off-On, Contact Current Max:18A, Contact Voltage AC Nom:125V, Switch Mounting:Panel, Actuator / Cap Color:Amber, Illumination Color:Amber , RoHS Compliant: Yes
XR1BG33NV1XX 制造商:Eaton Corporation 功能描述:SWITCH, ROCKER, SPDT, 18A, 125VAC, BLACK, Contact Configuration:SPDT, Switch Ope