R2061 Series
12345
Rev.1.00 - 37 -
The alarm function can be set by presetting desired alarm time in the alarm registers (the Alarm_W Registers for
the day-of-week digit settings and both the Alarm_W Registers and the Alarm_D Registers for the hour and minute
digit settings) with the WALE and DALE bits once set to 0 and then to 1 in the Control Register 1. Note that the
WALE and DALE bits should be once set to 0 in order to disable the alarm interrupt circuit upon the coincidental
occurrence of a match between current time and preset alarm time in the process of setting the alarm function.
Interval (1min.) during which a match
between current time and preset alarm time
occurs
current time =
preset alarm time
WALE
←
1
(DALE)
current time =
preset alarm time
WAFG
←
0
(DAFG)
/INTR
WALE
←
1
(DALE)
WALE
←
1
(DALE)
current time =
preset alarm time
WALE
←
0
(DALE)
current time =
preset alarm time
/INTR
After setting WALE(DALW) to 0, Alarm registers is set to current time, and WALE(DALE) is set to 1, /INTR will be
not driven to “L” immediately, /INTR will be driven to “L” at next alarm setting time.
G
Periodic Interrupt
Setting of the periodic selection bits (CT2 to CT0) enables periodic interrupt to the CPU. There are two waveform
modes: pulse mode and level mode. In the pulse mode, the output has a waveform duty cycle of around 50%. In
the level mode, the output is cyclically driven low and, when the CTFG bit is set to 0, the output is return to High
(OFF).
Description
CT2
CT1
CT0
Wave form mode
Interrupt Cycle and Falling Timing
0
0
0
-
OFF(H)
0
0
1
-
Fixed at “L”
0
1
0
Pulse Mode *1)
2Hz(Duty50%)
0
1
1
Pulse Mode *1)
1Hz(Duty50%)
1
0
0
Level Mode *2)
Once per 1 second (Synchronized with
Second counter increment)
1
0
1
Level Mode *2)
Once per 1 minute (at 00 seconds of every
Minute)
1
1
0
Level Mode *2)
Once per hour (at 00 minutes and 00
Seconds of every hour)
1
1
1
Level Mode *2)
Once per month (at 00 hours, 00 minutes,
and 00 seconds of first day of every month)
*1) Pulse Mode:
2-Hz and 1-Hz clock pulses are output in synchronization with the increment of the second counter as
illustrated in the timing chart below.
(Default)