QUAD T1/E1/J1 FRAMER/LIU COMBO - T1 REGISTER DESCRIPTION
REV. V1.2.0
T
ABLE
58: LAPD B
UFFER
0 C
ONTROL
R
EGISTER
(LAPDBCR0) H
EX
A
DDRESS
: 0
X
n600
B
IT
F
UNCTION
T
YPE
D
EFAULT
D
ESCRIPTION
-O
PERATION
7-0
LAPD Buffer 0
R/W
0
LAPD Buffer 0 (96-Bytes) Auto Incrementing
This register is used to transmit and receive LAPD messages within
buffer 0 of the HDLC controller. Any one of the three HDLC control-
ler can be chosen in the LAPD Select Register (0xn11B). Users
should determine the next available buffer by reading the BUFAVAL
bit (bit 7 of the Transmit Data Link Byte Count Register 1 (address
0xn114), Register 2 (0xn144) and Register 3 (0xn154) depending on
which HDLC controller is selected. If buffer 0 is available, writing to
buffer 0 will insert the message into the outgoing LAPD frame after
the LAPD message is sent and the data from the transmit buffer
cannot be retrieved.
After detecting the Receive end of transfer interrupt (RxEOT), users
should read the RBUFPTR bit (bit 7 of the Receive Data Link Byte
Count Register 1 (address 0xn115), Register 2 (0xn145), or Regis-
ter 3 (0xn155) depending on which HDLC controller is selected) to
determine which buffer contains the received LAPD message ready
to be read. If RBUFPTR bit indicates that buffer 0 is available to be
read, reading buffer 0 (Register 0xn600) continuously will retrieve
the entire received LAPD message.
N
OTE
:
When writing to or reading from Buffer 0, the register is
automatically incremented such that the entire 96 Byte
LAPD message can be written into or read from buffer 0
(Register 0xn600) continuously.
T
ABLE
59: LAPD B
UFFER
1 C
ONTROL
R
EGISTER
(LAPDBCR1) H
EX
A
DDRESS
: 0
X
n700
B
IT
F
UNCTION
T
YPE
D
EFAULT
D
ESCRIPTION
-O
PERATION
7-0
LAPD Buffer 1
R/W
0
LAPD Buffer 1 (96-Bytes) Auto Incrementing
This register is used to transmit and receive LAPD messages within
buffer 1 of the HDLC controller. Any one of the three HDLC control-
ler can be is chosen in the LAPD Select Register (0xn11B). Users
should determine the next available buffer by reading the BUFAVAL
bit (bit 7 of the Transmit Data Link Byte Count Register 1 (address
0xn114), Register 2 (0xn144) and Register 3 (0xn154) depending on
which HDLC controller is selected. If buffer 1 is available, writing to
buffer 1 will insert the message into the outgoing LAPD frame after
the LAPD message is sent and the data from the transmit buffer 1
cannot be retrieved.
After detecting the Receive end of transfer interrupt (RxEOT), users
should read the RBUFPTR bit (bit 7 of the Receive Data Link Byte
Count Register 1 (address 0xn115), Register 2 (0xn145), or Regis-
ter 3 (0xn155) depending on which HDLC controller is selected) to
determine which buffer contains the received LAPD message ready
to be read. If RBUFPTR bit indicates that buffer 1 is available to be
read, reading buffer 1 (Register 0xn700) continuously will retrieve
the entire received LAPD message.
N
OTE
:
When writing to or reading from Buffer 0, the register is
automatically incremented such that the entire 96 Byte
LAPD message can be written into or read from buffer 0
(Register 0xn600) continuously.