參數(shù)資料
型號(hào): AM79C970AKC
廠商: ADVANCED MICRO DEVICES INC
元件分類: 微控制器/微處理器
英文描述: PCnet-PCI II Single-Chip Full-Duplex Ethernet Controller for PCI Local Bus Product
中文描述: 2 CHANNEL(S), 10M bps, LOCAL AREA NETWORK CONTROLLER, PQFP13
封裝: CARRIER RING, PLASTIC, QFP-132
文件頁(yè)數(shù): 73/219頁(yè)
文件大?。?/td> 1065K
代理商: AM79C970AKC
第1頁(yè)第2頁(yè)第3頁(yè)第4頁(yè)第5頁(yè)第6頁(yè)第7頁(yè)第8頁(yè)第9頁(yè)第10頁(yè)第11頁(yè)第12頁(yè)第13頁(yè)第14頁(yè)第15頁(yè)第16頁(yè)第17頁(yè)第18頁(yè)第19頁(yè)第20頁(yè)第21頁(yè)第22頁(yè)第23頁(yè)第24頁(yè)第25頁(yè)第26頁(yè)第27頁(yè)第28頁(yè)第29頁(yè)第30頁(yè)第31頁(yè)第32頁(yè)第33頁(yè)第34頁(yè)第35頁(yè)第36頁(yè)第37頁(yè)第38頁(yè)第39頁(yè)第40頁(yè)第41頁(yè)第42頁(yè)第43頁(yè)第44頁(yè)第45頁(yè)第46頁(yè)第47頁(yè)第48頁(yè)第49頁(yè)第50頁(yè)第51頁(yè)第52頁(yè)第53頁(yè)第54頁(yè)第55頁(yè)第56頁(yè)第57頁(yè)第58頁(yè)第59頁(yè)第60頁(yè)第61頁(yè)第62頁(yè)第63頁(yè)第64頁(yè)第65頁(yè)第66頁(yè)第67頁(yè)第68頁(yè)第69頁(yè)第70頁(yè)第71頁(yè)第72頁(yè)當(dāng)前第73頁(yè)第74頁(yè)第75頁(yè)第76頁(yè)第77頁(yè)第78頁(yè)第79頁(yè)第80頁(yè)第81頁(yè)第82頁(yè)第83頁(yè)第84頁(yè)第85頁(yè)第86頁(yè)第87頁(yè)第88頁(yè)第89頁(yè)第90頁(yè)第91頁(yè)第92頁(yè)第93頁(yè)第94頁(yè)第95頁(yè)第96頁(yè)第97頁(yè)第98頁(yè)第99頁(yè)第100頁(yè)第101頁(yè)第102頁(yè)第103頁(yè)第104頁(yè)第105頁(yè)第106頁(yè)第107頁(yè)第108頁(yè)第109頁(yè)第110頁(yè)第111頁(yè)第112頁(yè)第113頁(yè)第114頁(yè)第115頁(yè)第116頁(yè)第117頁(yè)第118頁(yè)第119頁(yè)第120頁(yè)第121頁(yè)第122頁(yè)第123頁(yè)第124頁(yè)第125頁(yè)第126頁(yè)第127頁(yè)第128頁(yè)第129頁(yè)第130頁(yè)第131頁(yè)第132頁(yè)第133頁(yè)第134頁(yè)第135頁(yè)第136頁(yè)第137頁(yè)第138頁(yè)第139頁(yè)第140頁(yè)第141頁(yè)第142頁(yè)第143頁(yè)第144頁(yè)第145頁(yè)第146頁(yè)第147頁(yè)第148頁(yè)第149頁(yè)第150頁(yè)第151頁(yè)第152頁(yè)第153頁(yè)第154頁(yè)第155頁(yè)第156頁(yè)第157頁(yè)第158頁(yè)第159頁(yè)第160頁(yè)第161頁(yè)第162頁(yè)第163頁(yè)第164頁(yè)第165頁(yè)第166頁(yè)第167頁(yè)第168頁(yè)第169頁(yè)第170頁(yè)第171頁(yè)第172頁(yè)第173頁(yè)第174頁(yè)第175頁(yè)第176頁(yè)第177頁(yè)第178頁(yè)第179頁(yè)第180頁(yè)第181頁(yè)第182頁(yè)第183頁(yè)第184頁(yè)第185頁(yè)第186頁(yè)第187頁(yè)第188頁(yè)第189頁(yè)第190頁(yè)第191頁(yè)第192頁(yè)第193頁(yè)第194頁(yè)第195頁(yè)第196頁(yè)第197頁(yè)第198頁(yè)第199頁(yè)第200頁(yè)第201頁(yè)第202頁(yè)第203頁(yè)第204頁(yè)第205頁(yè)第206頁(yè)第207頁(yè)第208頁(yè)第209頁(yè)第210頁(yè)第211頁(yè)第212頁(yè)第213頁(yè)第214頁(yè)第215頁(yè)第216頁(yè)第217頁(yè)第218頁(yè)第219頁(yè)
P R E L I M I N A R Y
AMD
73
Am79C970A
Error Detection
The MAC engine provides several facilities which report
and recover from errors on the medium. In addition, it
protects the network from gross errors due to inability of
the host to keep pace with the MAC engine activity.
On completion of transmission, the following transmit
status is available in the appropriate Transmit Message
Descriptor (TMD) and Control and Status Register
(CSR) areas:
I
The number of transmission retry attempts (ONE,
MORE, RTRY, and TRC).
I
Whether the MAC engine had to Defer (DEF) due to
channel activity.
I
Excessive deferral (EXDEF), indicating that the
transmitter has experienced Excessive Deferral on
this transmit frame, where Excessive Deferral is de-
fined in ISO 8802-3 (IEEE/ANSI 802.3).
I
Loss of Carrier (LCAR), indicating that there was an
interruption in the ability of the MAC engine to
monitor its own transmission. Repeated LCAR er-
rors indicate a potentially faulty transceiver or net-
work connection.
I
Late Collision (LCOL) indicates that the transmission
suffered a collision after the slot time. This is indica-
tive of a badly configured network. Late collisions
should not occur in a normal operating network.
I
Collision Error (CERR) indicates that the transceiver
did not respond with an SQE Test message within
the first 4
μ
s after a transmission was completed.
This may be due to a failed transceiver,
disconnected or faulty transceiver drop cable, or the
fact the transceiver does not support this feature (or
it is disabled).
In addition to the reporting of network errors, the MAC
engine will also attempt to prevent the creation of any
network error due to the inability of the host to service
the MAC engine. During transmission, if the host fails to
keep the transmit FIFO filled sufficiently, causing an un-
derflow, the MAC engine will guarantee the message is
either sent as a runt packet (which will be deleted by the
receiving station) or has an invalid FCS (which will also
cause the receiver to reject the message).
The status of each receive message is available in the
appropriate Receive Message Descriptor (RMD) and
CSR areas. All received frames are passed to the host
regardless of any error. The FRAM error will only be re-
ported if an FCS error is detected and there are a non
integral number of bytes in the message.
During the reception, the FCS is generated on every se-
rial bit (including the dribbling bits) coming from the ca-
ble, although the internally saved FCS value is only
updated on the eighth bit (on each byte boundary). The
MAC engine will ignore up to 7 additional bits at the end
of a message (dribbling bits), which can occur under
normal network operating conditions. The framing error
is reported to the user as follows:
I
If the number of dribbling bits are 1 to 7 and there is
no FCS error, then there is no Framing error
(FRAM = 0).
I
If the number of dribbling bits are 1 to 7 and there is a
FCS error, then there is also a Framing error
(FRAM = 1).
I
If the number of dribbling bits is ZERO, then there is
no Framing error. There may or may not be a
FCS error.
I
If the number of dribbling bits is EIGHT, then there is
no Framing error. FCS error will be reported and the
receive message count will indicated one extra byte.
Counters are provided to report the Receive Collision
Count and Runt Packet Count, for network statistics and
utilization calculations.
Note that if the MAC engine detects a received frame
which has a 00b pattern in the preamble (after the first
8-bits which are ignored), the entire frame will be ig-
nored. The MAC engine will wait for the network to go
inactive before attempting to receive additional frames.
Media Access Management
The basic requirement for all stations on the network is
to provide fairness of channel allocation. The
802.3/Ethernet protocols define a media access mecha-
nism which permits all stations to access the channel
with equality. Any node can attempt to contend for the
channel by waiting for a predetermined time (Inter Pack-
et Gap) after the last activity, before transmitting on the
media. The channel is a multidrop communications me-
dia (with various topological configurations permitted)
which allows a single station to transmit and all other
stations to receive. If two nodes simultaneously contend
for the channel, their signals will interact causing loss of
data, defined as a collision. It is the responsibility of the
MAC to attempt to avoid and recover from a collision, to
guarantee data integrity for the end-to-end transmission
to the receiving station.
Medium Allocation
The IEEE/ANSI 802.3 Standard (ISO/IEC 8802-3 1990)
requires that the CSMA/CD MAC monitor the medium
for traffic by watching for carrier activity. When carrier is
detected, the media is considered busy, and the MAC
should defer to the existing message.
The ISO 8802-3 (IEEE/ANSI 802.3) Standard also al-
lows optional two part deferral after a receive message.
See ANSI/IEEE Std 802.3-1990 Edition, 4.2.3.2.1:
Note: It s possible for the PLS carrier sense ndication to
fail to be asserted during a collision on the media. If the
deference process simply times the interFrame gap
based on this indication it is possible for a short
相關(guān)PDF資料
PDF描述
AM79C970A PCnet-PCI II Single-Chip Full-Duplex Ethernet Controller for PCI Local Bus Product
AM79C970AVCW PCnet-PCI II Single-Chip Full-Duplex Ethernet Controller for PCI Local Bus Product
AM79C970 PCnetTM-PCI Single-Chip Ethernet Controller for PCI Local Bus
AM79C971VCW PCnet⑩-FAST Single-Chip Full-Duplex 10/100 Mbps Ethernet Controller for PCI Local Bus
AM79C971 PCnet⑩-FAST Single-Chip Full-Duplex 10/100 Mbps Ethernet Controller for PCI Local Bus
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AM79C970AKC\\W 制造商:Rochester Electronics LLC 功能描述:- Bulk 制造商:Advanced Micro Devices 功能描述:
AM79C970AKC\W 制造商:Rochester Electronics LLC 功能描述:- Bulk
AM79C970AKCW 制造商:AMD 制造商全稱:Advanced Micro Devices 功能描述:PCnet-PCI II Single-Chip Full-Duplex Ethernet Controller for PCI Local Bus Product
AM79C970AVC 制造商:Advanced Micro Devices 功能描述:
AM79C970AVC\\W 制造商:Advanced Micro Devices 功能描述: 制造商:Rochester Electronics LLC 功能描述: