參數(shù)資料
型號: PM73488
廠商: PMC-SIERRA INC
元件分類: 數(shù)字傳輸電路
英文描述: 5 Gbit/s ATM Switch Fabric Element
中文描述: ATM SWITCHING CIRCUIT, PBGA596
封裝: EPBGA-596
文件頁數(shù): 54/135頁
文件大小: 1735K
代理商: PM73488
PMC-Sierra, Inc.
PM73488 QSE
L
PMC-980616
Issue 3
5 Gbit/s ATMSwitch Fabric Element
Released
Datasheet
56
The failure conditions detected by the ORT on
g
, and the actions taken are summarized in Table 12.
5. 9. Types of Failures and Their Manifestation
Possible faults, the effects and how they affect the network are shown in Table 13.
Table 12. Failure Conditions, Switch Fabric-to-ORT Interface
Fault Detected on g
Action Taken
Comment
Cannot lock to special coding
and guaranteed transitions on
SE_SOC_IN.
No BP sent out on
h
. All data discarded.
SE_INPUT_PORT_FAIL signaled to the
microprocessor.
Withholding BP on
h
signals to the
previous stage that the port should not
be used.
Invalid cell present coding on
SE_D_IN(3:0).
No BP sent out on
h
. All data discarded.
SE_INPUT_PORT_FAIL signaled to the
microprocessor.
Most likely due to unconnected input
lines that are pulled up or down.
Withholding BP on
h
signals to the
previous stage that the port should not
be used.
Bad idle cell coding on
SE_D_IN(3:0).
No BP sent out on
h
. All data discarded.
SE_INPUT_PORT_FAIL signaled to the
microprocessor.
Withholding BP on
h
signals to the
previous stage that the port should not
be used.
Parity fail.
ACK sent out on
h
.
Parity errored cell dropped.
TX_PARITY_FAIL signaled to the
microprocessor.
ACK already sent by the time the QRT
has detected a parity error. Note that in
this case we have ACKed a cell that was
dropped.
Table 13. Faults
Fault
Manifestation
Effect on Network
Wire Connection
Data line from SE_D(3:0) stuck at 0
or 1.
Invalid idle cell, with some
10/01 fail and parity error.
Port shut down on receipt of first bad idle cell
until condition is fixed, as port failure is sent back
to source of data by the lack of BP indication.
SE_SOC line stuck at 0 or 1.
Loss of lock on special
coding on SE_SOC_IN.
Port shut down until condition is fixed, as port
failure is sent back to source of data by the lack of
BP indication.
BP_ACK line stuck at 0 or 1.
Loss of lock on special
coding on BP_ACK_IN.
Port shut down until the condition is fixed.
Bridging fault within a port.
Invalid idle cell, with some
10/01 fail and parity error.
Port shut down on receipt of first bad idle cell
until condition is fixed, as port failure is sent back
to source of data by the lack of BP indication.
QRT and QSE Port Failures
Loss of lock on special
coding on SE_SOC_IN.
Port shut down until condition is fixed, as port
failure is sent back to source of data by the lack of
BP indication.
相關(guān)PDF資料
PDF描述
PM7349 Ultraframer DS3/E3/DS2/E2/DS1/E1/DS0
PM7350 Dual Serial Link, PHY Multiplexer
PM7350-PI DUAL SERIAL LINK PHY MULTIPLEXER
PM7351 OCTAL SERIAL LINK MULTIPLEXER
PM7351-BI OCTAL SERIAL LINK MULTIPLEXER
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
PM73488PI 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Telecommunication IC
PM73488-PI 制造商:Rochester Electronics LLC 功能描述: 制造商:PMC-Sierra 功能描述:
PM7349 制造商:PMC 制造商全稱:PMC 功能描述:Quad J2, E3 and DS-3 Framer