absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage range, V
DD
(see Note 1)
I/O supply voltage range:
–
0.5 V to 2.4 V
–
0.5 V to 4 V
–
0.5 V to 4 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VDDS (see Note 1)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VDDO (see Note 1)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage on any SSTL input terminal
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage on any SSTL output terminal
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage on any LVDS input terminal
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage on any LVDS output terminal
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage on any LVTTL input terminal
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage on any LVTTL output terminal
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrostatic discharge (see Note 2)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Case temperature under bias
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Junction temperature under bias
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
–
0.5 V to VDDO+0.5 V
–
0.5 V to VDDO+0.5 V
–
0.5 V to VDDS+0.5 V
–
0.5 V to VDDS+0.5 V
–
0.5 V to VDDS+0.5 V
–
0.5 V to VDDS+0.5 V
Class 3, A:2 kV
–
55
°
C to 125
°
C
–
55
°
C to 150
°
C
–
65
°
C to 150
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under
“
absolute maximum ratings
”
may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under
“
recommended operating conditions
”
is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values are with respect to the GND terminals.
2. This rating is measured using MIL-STD-883C Method, 3015.7.
recommended operating conditions
MIN
NOM
MAX
UNIT
Supply voltage, VDD
I/O supply voltage, VDDS
1.71
1.8
1.89
V
3.135
3.3
3.465
V
I/O supply voltage, VDDO
2.375
2.5
2.625
V
°
C
Operating free-air temperature, TA
0
70
supply voltage power dissipation
TEST CONDITIONS
MIN
NOM
MAX
510
UNIT
VDD supply voltage power dissipation, PD,VDD
VDDS I/O supply voltage power dissipation, PD,VDDS
VDDO I/O supply voltage power dissipation, PD,VDDO
CL = 15 pF, a5 pattern used
CL 15 F, a5 attern used
400
mW
580