8- 22
MC68341 USER’S MANUAL
MOTOROLA
Disabled—TOUT is disabled and three-stated.
Toggle Mode—If the timer is disabled (SWR = 0) when this encoding is programmed,
TOUT is immediately set to zero. If the timer is enabled (SWR = 1), time-out events
(counter reaches $0000) toggle TOUT. In the input capture/output compare mode,
TOUT is immediately set to zero if the timer is disabled (SWR = 0). If the timer is
enabled (SWR = 1), timer compare events toggle TOUT. (Timer compare events occur
when the counter reaches the value stored in the COM.)
Zero Mode—If the timer is disabled (SWR = 0) when this encoding is programmed,
TOUT is immediately set to zero. If the timer is enabled (SWR = 1), TOUT will be set to
zero at the next time-out. In the input capture/output compare mode, TOUT is
immediately set to zero if the timer is disabled (SWR = 0). If the timer is enabled (SWR
= 1), TOUT will be set to zero at time-outs and set to one at timer compare events. If the
COM is $0000, TOUT will be set to zero at the time-out/timer compare event.
One Mode—If the timer is disabled (SWR = 0) when this encoding is programmed,
TOUT is immediately set to one. If the timer is enabled (SWR = 1), TOUT will be set to
one at the next time-out. In the input capture/output compare mode, TOUT is
immediately set to one if the timer is disabled (SWR = 0). If the timer is enabled (SWR =
1), TOUT will be set to one at timeouts and set to zero at timer compare events. If the
COM is $0000, TOUT will be set to one at the time-out/timer compare event.
8.4.4 Status Register (SR)
The SR contains timer status information as well as the state of the prescaler. This
register is updated on the rising edge of the system clock when a read of its location is not
in progress, allowing the most current information to be contained in this register. The
register can be read, and the TO, TG, and TC bits can be written when the timer module is
enabled (i.e., the STP bit in the MCR is cleared).
SR
$608
15
14
13
12
11
10
9876543210
IRQ
TO
TG
TC
TGL
ON
OUT
COM
PO7
PO6
PO5
PO4
PO3
PO2
PO1
PO0
RESET ( TGATE NEGATED):
0000100011111111
RESET ( TGATE ASSERTED):
0000000011111111
Supervisor/User
IRQ—Interrupt Request bit
The positioning of this bit in the most significant location in this register allows it be
conditionally tested as if it were a signed binary integer.
1 = An interrupt condition has occurred. This bit is the logical OR of the enabled TO,
TG, and TC interrupt bits.
0 = The bit(s) that caused the interrupt condition has been cleared. If an IRQ≈ signal
has been asserted, it is negated when this bit is cleared.