PSB 7230
Register Description
Semiconductor Group
109
Data Sheet 1998-07-01
RSCO
Receive Time-slot Continuous
When RSCO is equal to one, the time-slot capacity (normally given by
register RCCR, between 1 and 256 bits) is
“infinity”. This means that the
time-slot will be always “active” so that data can be permanently received if
RAC = 1.
If RFDIS = 0, and if the time-slot count logic has been reset (by issuing
RRES while RAC = 0), time-slot logic can start operation and thus “activate”
a time-slot only after the first frame sync pulse is detected (i.e. on FSC, RFS,
or TFS, whichever has been selected). The time-slot offset register TSAR +
bit RCS0 mark the instant when the “infinite” time-slot will be activated after
the first frame sync pulse has occurred. If RFDIS = 1, reception can start
immediately, without the necessity to wait for the first frame sync pulse.
Receive Frame Sync Disregard
When RFDIS is “1”, the time-slot generation logic disregards frame syncs.
In particular, if RSCO = 1 and RFDIS = 1, receive time-slot is immediately
considered as permanently “active”, and remains activated as long as this
condition prevails.
Transmit Time-slot Continuous
When TSCO is equal to one, the time-slot capacity (normally given by
register XCCR, between 1 and 256 bits) is “infinity”. This means that the
time-slot will be always “active” so that data can be permanently transmitted
if XAC = 1.
If TFDIS = 0, and if the time-slot count logic has been reset (by issuing
XRES while XAC = 0), time-slot logic can start operation and thus “activate”
a time-slot only after the first frame sync pulse is detected (i.e. on FSC, RFS,
or TFS, whichever has been selected). The time-slot offset register TSAX +
bit XCS0 mark the instant when the “infinite” time-slot will be activated after
the first frame sync pulse has occurred. If TFDIS = 1, transmission can start
immediately, without the necessity to wait for the first frame sync pulse.
Transmit Frame Sync Disregard
When TFDIS is “1”, the time-slot generation logic disregards frame syncs. In
particular, if TSCO = 1 and TFDIS = 1, transmit time-slot is immediately
considered as permanently “active”, and remains activated as long as this
condition prevails.
RFDIS
TSCO
TFDIS