參數(shù)資料
型號(hào): AM79C974
廠商: Advanced Micro Devices, Inc.
英文描述: PCnetTM-SCSI Combination Ethernet and SCSI Controller for PCI Systems
中文描述: PCnetTM -的SCSI結(jié)合以太網(wǎng)和SCSI控制器PCI系統(tǒng)
文件頁(yè)數(shù): 71/153頁(yè)
文件大?。?/td> 838K
代理商: AM79C974
第1頁(yè)第2頁(yè)第3頁(yè)第4頁(yè)第5頁(yè)第6頁(yè)第7頁(yè)第8頁(yè)第9頁(yè)第10頁(yè)第11頁(yè)第12頁(yè)第13頁(yè)第14頁(yè)第15頁(yè)第16頁(yè)第17頁(yè)第18頁(yè)第19頁(yè)第20頁(yè)第21頁(yè)第22頁(yè)第23頁(yè)第24頁(yè)第25頁(yè)第26頁(yè)第27頁(yè)第28頁(yè)第29頁(yè)第30頁(yè)第31頁(yè)第32頁(yè)第33頁(yè)第34頁(yè)第35頁(yè)第36頁(yè)第37頁(yè)第38頁(yè)第39頁(yè)第40頁(yè)第41頁(yè)第42頁(yè)第43頁(yè)第44頁(yè)第45頁(yè)第46頁(yè)第47頁(yè)第48頁(yè)第49頁(yè)第50頁(yè)第51頁(yè)第52頁(yè)第53頁(yè)第54頁(yè)第55頁(yè)第56頁(yè)第57頁(yè)第58頁(yè)第59頁(yè)第60頁(yè)第61頁(yè)第62頁(yè)第63頁(yè)第64頁(yè)第65頁(yè)第66頁(yè)第67頁(yè)第68頁(yè)第69頁(yè)第70頁(yè)當(dāng)前第71頁(yè)第72頁(yè)第73頁(yè)第74頁(yè)第75頁(yè)第76頁(yè)第77頁(yè)第78頁(yè)第79頁(yè)第80頁(yè)第81頁(yè)第82頁(yè)第83頁(yè)第84頁(yè)第85頁(yè)第86頁(yè)第87頁(yè)第88頁(yè)第89頁(yè)第90頁(yè)第91頁(yè)第92頁(yè)第93頁(yè)第94頁(yè)第95頁(yè)第96頁(yè)第97頁(yè)第98頁(yè)第99頁(yè)第100頁(yè)第101頁(yè)第102頁(yè)第103頁(yè)第104頁(yè)第105頁(yè)第106頁(yè)第107頁(yè)第108頁(yè)第109頁(yè)第110頁(yè)第111頁(yè)第112頁(yè)第113頁(yè)第114頁(yè)第115頁(yè)第116頁(yè)第117頁(yè)第118頁(yè)第119頁(yè)第120頁(yè)第121頁(yè)第122頁(yè)第123頁(yè)第124頁(yè)第125頁(yè)第126頁(yè)第127頁(yè)第128頁(yè)第129頁(yè)第130頁(yè)第131頁(yè)第132頁(yè)第133頁(yè)第134頁(yè)第135頁(yè)第136頁(yè)第137頁(yè)第138頁(yè)第139頁(yè)第140頁(yè)第141頁(yè)第142頁(yè)第143頁(yè)第144頁(yè)第145頁(yè)第146頁(yè)第147頁(yè)第148頁(yè)第149頁(yè)第150頁(yè)第151頁(yè)第152頁(yè)第153頁(yè)
P R E L I M I N A R Y
AMD
71
Am79C974
network bit time period following the completion of
transmission, then the Am79C974 controller will set the
CERR bit in CSR0. CERR will be asserted in 10BASE-T
mode after transmit if T-MAU is in Link Fail state. CERR
will never cause
INTA
to be activated. It will, however,
set the ERR bit CSR0.
Receive Operation
The receive operation and features of the Am79C974
controller are controlled by programmable options.
Address Matching
The Am79C974 controller supports three types of ad-
dress matching: unicast, multicast, and broadcast. The
normal address matching procedure can be modified by
programming three bits in the MODE register (PROM,
DRCVBC, and DRCVPA).
If the first bit received after the start of frame delimiter
(the least significant bit of the first byte of the destination
address field) is 0, the frame is unicast, which indicates
that the frame is meant to be received by a single node.
If the first bit received is 1, the frame is multicast, which
indicates that the frame is meant to be received by a
group of nodes. If the destination address field contains
all ones, the frame is broadcast, which is a special type
of multicast. Frames with the broadcast address in the
destination address field are meant to be received by all
nodes on the local area network.
When a unicast frame arrives at the Am79C974 control-
ler, the controller will accept the frame if the destination
address field of the incoming frame exactly matches the
6-byte station address stored in the PADR registers
(CSR12, CSR13, and CSR14). The byte ordering is
such that the first byte received from the network (after
the SFD) must match the least significant byte of CSR12
(PADR[7:0]), and the sixth byte received must match the
most significant byte of CSR14 (PADR[47:40]).
If DRCVPA (bit 13 in the MODE register) is set. the
Am79C974 controller will not accept unicast frames.
If the incoming frame is multicast the Am79C974 con-
troller performs a calculation on the contents of the des-
tination address field to determine whether or not to
accept the frame. This calculation is explained in the
section that describes the Logical Address Filter
(LADRF).
If all bits of the LADRF registers are 0 no multicast
frames are accepted, except for broadcast frames.
Although broadcast frames are classified as special
multicast frames, they are treated differently by the
Am79C974 controller hardware. Broadcast frames are
always accepted, except when DRCVBC (bit 14 in the
MODE register) is set.
None of the address filtering described above applies
when the Am79C974 controller is operating in the
promiscuous mode. In the promiscuous mode, all prop-
erly formed packets are received, regardless of the con-
tents of their destination address fields. The
promiscuous mode overrides the Disable Receive
Broadcast bit (DRCVBC bit l4 in the MODE register) and
the Disable Receive Physical Address bit (DRCVPA, bit
13 MODE register).
The Am79C974 controller operates in promiscuous
mode when PROM (bit 15 in the MODE register) is set.
Receive Function Programming
Automatic pad field stripping is enabled by setting the
ASTRP_RCV bit in CSR4. This can provide flexibility in
the reception of messages using the 802.3 frame
format.
All receive frames can be accepted by setting the PROM
bit in CSR15. When PROM is set, the Am79C974 con-
troller will attempt to receive all messages, subject to
minimum frame enforcement. Promiscuous mode over
rides the effect of the Disable Receive Broadcast bit on
receiving broadcast frames.
The point at which the BMU will start to transfer data
from the receive FIFO to buffer memory is controlled by
the RCVFW bits in CSR80. The default established dur-
ing H_RESET is 10b which sets the threshold flag at
64bytes empty.
Automatic Pad Stripping
During reception of an 802.3 frame the pad field can be
stripped automatically. ASTRP_RCV (CSR4, bit 0) = 1
enables the automatic pad stripping feature. The pad
field will be stripped before the frame is passed to the
FIFO, thus preserving FIFO space for additional frames.
The FCS field will also be stripped, since it is computed
at the transmitting station based on the data and pad
field characters, and will be invalid for a receive frame
that has had the pad characters stripped.
The number of bytes to be stripped is calculated from
the embedded length field (as defined in the ISO 8802-3
(IEEE/ANSI 802.3) definition) contained in the frame.
The length indicates the actual number of LLC data
bytes contained in the message. Any received frame
which contains a length field less than 46 bytes will have
the pad field stripped (if ASTRP_RCV is set). Receive
frames which have a length field of 46 bytes or greater
will be passed to the host unmodified.
Since any valid Ethernet Type field value will always be
greater than a normal 802.3 Length field (
46), the
Am79C974 controller will not attempt to strip valid
Ethernet frames.
Note that for some network protocols, the value passed
in the Ethernet Type and/or 802.3 Length field is not
compliant with either standard and may cause
problems.
相關(guān)PDF資料
PDF描述
AM79C974KCW PCnetTM-SCSI Combination Ethernet and SCSI Controller for PCI Systems
AM79C975 PCnet⑩-FAST III Single-Chip 10/100 Mbps PCI Ethernet Controller with Integrated PHY
AM79C973 PCnet⑩-FAST III Single-Chip 10/100 Mbps PCI Ethernet Controller with Integrated PHY
AM79C973KCW PCnet⑩-FAST III Single-Chip 10/100 Mbps PCI Ethernet Controller with Integrated PHY
AM79C975KCW PCnet⑩-FAST III Single-Chip 10/100 Mbps PCI Ethernet Controller with Integrated PHY
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AM79C974KC 制造商:Advanced Micro Devices 功能描述:
AM79C974KC/W 制造商:未知廠家 制造商全稱:未知廠家 功能描述:LAN Node Controller
AM79C974KCW 制造商:AMD 制造商全稱:Advanced Micro Devices 功能描述:PCnetTM-SCSI Combination Ethernet and SCSI Controller for PCI Systems
AM79C975 制造商:AMD 制造商全稱:Advanced Micro Devices 功能描述:PCnet⑩-FAST III Single-Chip 10/100 Mbps PCI Ethernet Controller with Integrated PHY