792
6437E–ATARM–23-Apr-13
SAM9M11
The SD/SDIO Card bus allows dynamic configuration of the number of data lines. After power
up, by default, the SD/SDIO Card uses only DAT0 for data transfer. After initialization, the host
can change the bus width (number of active data lines).
37.9.1
SDIO Data Transfer Type
SDIO cards may transfer data in either a multi-byte (1 to 512 bytes) or an optional block format
(1 to 511 blocks), while the SD memory cards are fixed in the block transfer mode. The TRTYP
field in the HSMCI Command Register (HSMCI_CMDR) allows to choose between SDIO Byte or
SDIO Block transfer.
The number of bytes/blocks to transfer is set through the BCNT field in the HSMCI Block Regis-
ter (HSMCI_BLKR). In SDIO Block mode, the field BLKLEN must be set to the data block size
while this field is not used in SDIO Byte mode.
An SDIO Card can have multiple I/O or combined I/O and memory (called Combo Card). Within
a multi-function SDIO or a Combo card, there are multiple devices (I/O and memory) that share
access to the SD bus. In order to allow the sharing of access to the host among multiple devices,
SDIO and combo cards can implement the optional concept of suspend/resume (Refer to the
SDIO Specification for more details). To send a suspend or a resume command, the host must
set the SDIO Special Command field (IOSPCMD) in the HSMCI Command Register.
37.9.2
SDIO Interrupts
Each function within an SDIO or Combo card may implement interrupts (Refer to the SDIO
Specification for more details). In order to allow the SDIO card to interrupt the host, an interrupt
function is added to a pin on the DAT[1] line to signal the card’s interrupt to the host. An SDIO
interrupt on each slot can be enabled through the HSMCI Interrupt Enable Register. The SDIO
interrupt is sampled regardless of the currently selected slot.
37.10 CE-ATA Operation
CE-ATA maps the streamlined ATA command set onto the MMC interface. The ATA task file is
mapped onto MMC register space.
CE-ATA utilizes five MMC commands:
GO_IDLE_STATE (CMD0): used for hard reset.
STOP_TRANSMISSION (CMD12): causes the ATA command currently executing to be
aborted.
FAST_IO (CMD39): Used for single register access to the ATA taskfile registers, 8 bit access
only.
RW_MULTIPLE_REGISTERS (CMD60): used to issue an ATA command or to access the
control/status registers.
RW_MULTIPLE_BLOCK (CMD61): used to transfer data for an ATA command.
CE-ATA utilizes the same MMC command sequences for initialization as traditional MMC
devices.
37.10.1
Executing an ATA Polling Command
1.
Issue READ_DMA_EXT with RW_MULTIPLE_REGISTER (CMD60) for 8kB of DATA.
2.
Read the ATA status register until DRQ is set.
3.
Issue RW_MULTIPLE_BLOCK (CMD61) to transfer DATA.
4.
Read the ATA status register until DRQ && BSY are set to 0.