1021
6437E–ATARM–23-Apr-13
SAM9M11
42.11.8
TSADCC Status Register
Name:
TSADCC_SR
Address:
0xFFFB001C
Access:
Read-only
EOCx: End of Conversion x
0 = Corresponding analog channel is disabled, or the conversion is not finished.
1 = Corresponding analog channel is enabled and conversion is complete.
OVREx: Overrun Error x
0 = No overrun error on the corresponding channel since the last read of TSADCC_SR.
1 = There has been an overrun error on the corresponding channel since the last read of TSADCC_SR.
DRDY: Data Ready
0 = No data has been converted since the last read of TSADCC_LCDR.
1 = At least one data has been converted and is available in TSADCC_LCDR.
GOVRE: General Overrun Error
0 = No General Overrun Error occurred since the last read of TSADCC_SR.
1 = At least one General Overrun Error has occurred since the last read of TSADCC_SR.
ENDRX: End of RX Buffer
0 = The Receive Counter Register has not reached 0 since the last write in TSADCC_RCR or TSADCC_RNCR.
1 = The Receive Counter Register has reached 0 since the last write in TSADCC_RCR or TSADCC_RNCR.
RXBUFF: RX Buffer Full
0 = TSADCC_RCR or TSADCC_RNCR have a value other than 0.
1 = Both TSADCC_RCR and TSADCC_RNCR have a value of 0.
PENCNT: Pen Contact
0 = No contact has been detected since the last read of TSADCC_SR or PENDET is at 0.
1 = At least one contact has been detected since the last read of TSADCC_SR.
NOCNT: No Contact
0 = No contact loss has been detected since the last read of TSADCC_SR or PENDET is at 0.
1 = At least one contact loss has been detected since the last read of TSADCC_SR.
31
30
29
28
27
26
25
24
–
OVREZ2
OVREZ1
OVREXP
–
EOCZ2
EOCZ1
EOCXP
23
22
21
20
19
18
17
16
–
NOCNT
PENCNT
RXBUFF
ENDRX
GOVRE
DRDY
15
14
13
12
11
10
9
8
OVRE7
OVRE6
OVRE5
OVRE4
OVRE3
OVRE2
OVRE1
OVRE0
76543210
EOC7
EOC6
EOC5
EOC4
EOC3
EOC2
EOC1
EOC0