290
6437E–ATARM–23-Apr-13
SAM9M11
1 = Multiple Errors Detected.
RECERR10: Recoverable Error in the page between the 2560th and the 2815th bytes
Fixed to 0 if TYPECORREC = 0.
0 = No Errors Detected.
1 = Errors Detected. If MUL_ERROR is 0, a single correctable error was detected. Otherwise, multiple uncorrected errors
were detected.
ECCERR10: ECC Error in the page between the 2560th and the 2815th bytes
Fixed to 0 if TYPECORREC = 0.
0 = No Errors Detected.
1 = A single bit error occurred in the ECC bytes.
Read ECC Parity 10 register, the error occurred at the location which contains a 1 in the least significant 24 bits.
MULERR10: Multiple Error in the page between the 2560th and the 2815th bytes
Fixed to 0 if TYPECORREC = 0.
0 = No Multiple Errors Detected.
1 = Multiple Errors Detected.
RECERR11: Recoverable Error in the page between the 2816th and the 3071st bytes
Fixed to 0 if TYPECORREC = 0.
0 = No Errors Detected.
1 = Errors Detected. If MUL_ERROR is 0, a single correctable error was detected. Otherwise, multiple uncorrected errors
were detected
ECCERR11: ECC Error in the page between the 2816th and the 3071st bytes
Fixed to 0 if TYPECORREC = 0.
0 = No Errors Detected.
1 = A single bit error occurred in the ECC bytes.
Read ECC Parity 11 register, the error occurred at the location which contains a 1 in the least significant 24 bits.
MULERR11: Multiple Error in the page between the 2816th and the 3071st bytes
Fixed to 0 if TYPECORREC = 0.
0 = No Multiple Errors Detected.
1 = Multiple Errors Detected.
RECERR12: Recoverable Error in the page between the 3072nd and the 3327th bytes
Fixed to 0 if TYPECORREC = 0
0 = No Errors Detected
1 = Errors Detected. If MUL_ERROR is 0, a single correctable error was detected. Otherwise multiple uncorrected errors
were detected
ECCERR12: ECC Error in the page between the 3072nd and the 3327th bytes
Fixed to 0 if TYPECORREC = 0
0 = No Errors Detected