28229-DSH-001-B
Mindspeed Technologies
1
-11
CX28224/5/9 Data Sheet
Introduction to IMA
Group
Interface
IMA_group_set ()
This function provides a direct interface to set the
CX28224/5/9 Group
parameters.
IMA_group_get ()
This function provides a direct interface to retrieve the
CX28224/5/9 Group
parameters.
IMA_group_FM_status ()
This function retrieves the current state of the parameters monitored by the
Facility Monitoring subsystem for the IMA Group layer.
IMA_group_PM_preset ()
This function allows the user to initialize the IMA Group PM statistics to arbitrary
values for the current interval of the 15 minute accumulation period.
IMA_group_PM_status ()
This function retrieves the states (from either the current or previous 15 minute
accumulation interval) of the IMA Group Performance Monitoring parameters.
Link
Interface
IMA_link_set ()
This function provides a direct interface to set the
CX28224/5/9 Link
parameters.
IMA_link_get ()
This function provides a direct interface to retrieve the
CX28224/5/9 Link
parameters.
IMA_link_FM_status ()
This function retrieves the current state of the parameters monitored by the
Facility Monitoring subsystem for the IMA Link layer.
IMA_link_PM_preset ()
This function allows the user to initialize the IMA Link PM statistics to arbitrary
values for the current interval of the 15 minute accumulation period.
IMA_link_PM_status ()
This function retrieves the states (from either the current or previous 15 minute
accumulation interval) of the IMA Link Performance Monitoring parameters.
PHY
Interface
IMA_phy_link_set ()
This function provides a direct interface to set the
CX28224/5/9 Link
parameters, per facility.
IMA_phy_link_get ()
This function provides a direct interface to retrieve the
CX28224/5/9 Link
parameters, per facility.
IMA_phy_link_FM_status ()
This function retrieves the current state of the parameters monitored by the
Failure Monitoring subsystem for the IMA Link layer, per facility.
IMA_phy_link_PM_preset ()
This function allows the user to initialize the IMA Group PM statistics to arbitrary
values for the current interval of the 15 minute accumulation period.
IMA_phy_link_PM_status ()
This function retrieves the states (from either the current or previous 15 minute
accumulation interval) of the IMA Link Performance Monitoring parameters, per
facility.
Monitor
IMA_mon()
This function is called to control the
CX28224/5/9 debugger.
User Defined
*USER_intr_disable()
This is an application defined function that disables interrupts from the IMA
hardware device.
*USER_intr_enable()
This is an application defined function that enables interrupts from the IMA
hardware device.
* USER_event ()
This is an application defined function that accepts asynchronous event
messages from the
CX28224/5/9 software.
Table 1-5. Software Function Summary (2 of 2)
Class
Function
Short Description