A-18
Mindspeed Technologies
28229-DSH-001-B
IMA Version 1.1 PICS Proforma
CX28224/5/9 Data Sheet
OAM.46 Does the implementation increment GR-FC each time the Config-
Aborted group failure condition is entered, as indicated in Table 19
on page 77?
M
(R-137)
Yes X No__
OAM.47 Does the implementation increment GR-FC each time the
Insufficient-Links group failure condition is entered, as indicated in
Table 19 on page 77?
M
(R-137)
Yes X No__
OAM.48 Does the implementation increment GR-FC-FE each time the Start-
up-FE group failure condition is entered, as indicated in Table 19
on page 77?
O
(O-25)
Yes X No__
OAM.49 Does the implementation increment GR-FC-FE each time the
Config-Aborted-FE group failure condition is entered, as indicated
in Table 19 on page 77?
O
(O-25)
Yes X No__
OAM.50 Does the implementation increment GR-FC-FE each time the
Insufficient-Links-FE group failure condition is entered, as
indicated in Table 19 on page 77?
O
(O-25)
Yes X No__
OAM.51 Does the implementation increment GR-FC-FE each the Blocked-FE
group failure condition is entered, as indicated in Table 19 on page
77?
O
(O-25)
Yes X No__
OAM.52 Does the implementation accumulate IMA performance
parameters over 15 minute intervals?
O
(O-26)
Yes X No__
OAM.53 Does the implementation accumulate IMA performance
parameters over 24 hour intervals?
O
(O-27)
Yes__ No X
OAM.54 Does the implementation keep the current/previous and recent
data?
(O-26)
M
(CR-7)
Yes X No__
OAM.55 Does the implementation use the current data for threshold
crossing?
(O-26)
M
(CR-8)
Yes__ No X
OAM.56 Does the implementation keep the current/previous and recent
data?
(O-27)
M
(CR-9)
Yes__ No X
OAM.57 Does the implementation use the current data for threshold
crossing?
(O-27)
M
(CR-10)
Yes__ No X
OAM.58 Does the implementation report a LIF failure alarm for the
persistence of a LIF defect at the NE?
M
(R-138)
Yes X No__
OAM.59 Does the implementation report a LODS failure alarm for the
persistence of a LODS defect at the NE?
M
(R-139)
Yes X No__
OAM.60 Does the implementation report a RFI-IMA failure alarm for the
persistence of a RDI-IMA defect at the NE?
M
(R-140)
Yes X No__
OAM.61 Does the implementation report Tx-Mis-Connected failure alarm
when the Tx link is detected as mis-connected?
M
(R-141)
Yes X No__
OAM.62 Does the implementation report Rx-Mis-Connected failure alarm
when the Rx link is detected as mis-connected?
M
(R-142)
Yes X No__
OAM.63 Does the implementation report a Tx Fault failure alarm for any
implementation specific Tx fault declared at the NE?
O
(O-28)
Yes__ No X
Table A-8. IMA Interface OAM Operation Functions (4 of 5)
Item
Protocol feature
Cond. for
Status
Pred.
Ref.
Support