參數(shù)資料
型號: T8100A
英文描述: H.100/H.110 Interface and Time-Slot Interchangers
中文描述: H.100/H.110接口和時隙Interchangers
文件頁數(shù): 25/112頁
文件大?。?/td> 1408K
代理商: T8100A
Lucent Technologies Inc.
21
Advance Data Sheet
November 1999
H.100/H.110 Interfaces and Time-Slot Interchangers
Ambassador T8100A, T8102, and T8105
2 Architecture and Functional
Description
(continued)
2.1 Register/Memory Maps
(continued)
2.1.4 Control Register Memory Space
(continued)
Table 30. FRPL: Frame Group B, Programmed
Output, Low, 0x24
Table 31. FRPH: Frame Group B, Programmed
Output, High, 0x25
Table 32. CLKERR1: Clock Error Register, Error
Indicator, 0x28
Table 33. CLKERR2: Clock Error Register, Current
Status, 0x29
Table 34. SYSERR: System Error Register, 0x2A
Table 35. CKW: Clock Error/Watchdog Masking
Register, 0x2B
Table 36. CLKERR3: Clock Error Register, Current
Status, 0x2C
Bit
7
6
5
4
3
2
1
0
Description
Programmed Output, Bit 7
Programmed Output, Bit 6
Programmed Output, Bit 5
Programmed Output, Bit 4
Programmed Output, Bit 3
Programmed Output, Bit 2
Programmed Output, Bit 1
Programmed Output, Bit 0
Bit
7
6
5
4
3
2
1
0
Description
Group A Output Pins Select, MSB
Group A Output Pins Select, LSB
(Reserved, Use 0)
Group B Output Pins Select
Programmed Output, Bit 11
Programmed Output, Bit 10
Programmed Output, Bit 9
Programmed Output, Bit 8
Bit
7
6
5
4
3
2
1
0
Description
C8A or Frame A Error
C8B or Frame B Error
/FR_COMPn Error
C16+ or C16– Error
C4n or C2 Error
SCLKX2
Error
SCLK Error
NETREF Error
Bit
7
6
5
4
3
2
1
0
Description
C8A or Frame A Fault Status
C8B or Frame B Fault Status
/FR_COMPn Fault Status
C16+ or C16– Fault Status
C4n or C2 Fault Status
SCLKX2
Fault Status
SCLK Fault Status
NETREF[2:1] Fault Status
Bit
7
6
5
4
3
2
1
0
Description
Even CAM Underflow Error (No Match)
Odd CAM Underflow Error (No Match)
Local CAM Underflow Error (No Match)
Even CAM Overflow or No-Match Error
Odd CAM Overflow or No-Match Error
Local CAM Overflow or No-Match Error
H-Bus Data Memory Access Error
Fallback Enable Indicator
Bit
7
6
5
4
3
2
1
0
Description
C8A and Frame A Error Mask
C8B and Frame B Error Mask
/FR_COMP Error Mask
C16+ and C16– Error Mask
/C4 and C2 Error Mask
SCLKX2
Error Mask
SCLK Error Mask
NETREF1 Error Mask
Bit
7
6
5
4
3
2
1
0
Description
(Reserved)
(Reserved)
NETREF2 Error
NETREF1 Error
(Reserved)
(Reserved)
(Reserved)
NETREF2 Error Mask
相關(guān)PDF資料
PDF描述
T8102A H.100/H.110 Interface and Time-Slot Interchangers
T8105A H.100/H.110 Interface and Time-Slot Interchangers
T8100 H.100/H.110 Interface and Time-Slot Interchanger
T8110 Version History
T8301 T8301 Internet Protocol Telephone Phone-On-A-Chip⑩ IP Solution DSP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
T8100A-BAL 制造商:Alcatel-Lucent 功能描述:ELECTRONIC COMPONENT
T8100A-BAL4DB 制造商:AGERE 功能描述:
T8100-D 制造商:GE Sensing & Inspection Technologies 功能描述:CO2/TEMP SENS WALL MNT DUAL OUT
T8100-E 制造商:GE Sensing & Inspection Technologies 功能描述:TRANSMITTER, CO2, HUMIDITY, TEMP 制造商:GE MEASUREMENT & CONTROL 功能描述:TRANSMITTER, CO2, HUMIDITY, TEMP; Plug Type:- ;RoHS Compliant: Yes 制造商:GE MEASUREMENT & CONTROL/GE SENSING 功能描述:TRANSMITTER, CO2, HUMIDITY, TEMP; Plug Type:- ;RoHS Compliant: Yes
T8100-E-D 制造商:GE Sensing & Inspection Technologies 功能描述:TRANSMITTER, CO2, HUMIDITY, TEMP 制造商:GE MEASUREMENT & CONTROL 功能描述:TRANSMITTER, CO2, HUMIDITY, TEMP; Plug Type:- ;RoHS Compliant: Yes 制造商:GE MEASUREMENT & CONTROL/GE SENSING 功能描述:TRANSMITTER, CO2, HUMIDITY, TEMP; Plug Type:- ;RoHS Compliant: Yes