2.5 Clocking Section
(continued)
2.5.7 Clock Fallback
(continued)
The following conditions must be met before fallback is
initiated:
I
Fallback must be enabled in register CKS.
I
Failure of one or more of the clocks selected through
the CKSEL bits in the CKM register.
I
All clocks which comprise the selection from CKSEL
must be unmasked in register CKW (see Section 2.7
Error Registers).
The devices contain a fallback register which enables a
backup set of controls for the clock resources during a
clock failure. In addition, a fallback state machine pro-
vides some basic decision-making for controlling some
of the clock outputs when the feature is enabled. While
slaving to the bus, the primary course of action in fall-
back is the swap between the A clocks and B clocks as
the primary synchronization sources. A slave may
become a master only under software control; i.e.,
there is no automatic promotion mechanism. As a mas-
ter, the devices detect their own failures and remove
their clocks from the bus. If a failure is detected on the
other main set (e.g., B master detects failures on the A
master), then the devices can assume the role of the
primary synchronization source by driving all compati-
bility clocks (H-MVIP and SC-Bus). Clock failures are
flagged through the CLKERR1, CLKERR2, and
CLKERR3 registers (Section 2.7 Error Registers).
Additional fallback details are discussed in relationship
to the clock registers in the next section. The divide-by-
4 block for XTALIN, shown in Figure 16, is used only for
fallback. See Figure 17 for a diagram of the basic state
machine which controls the A, B, and C (compatibility)
clocks. Figure 18 shows a diagram for programming the
device’s registers when a fallback condition is detected.
Figure 18 shows the steps required to program the reg-
isters when a fallback condition is detected.
Restarting the clocks after a fallback condition:
1. Clear the CKW register to prevent any more clock errors.
2. Clear CKM bit 5 (CCD) to be a slave.
3. Clear CKP bits 2 and 3 to prevent sourcing a compatility clock.
4. Set CKM bit 5 (CCD) to be a master again.
5. Set CKP bits 2 and 3 to drive the appropriate A or B clocks.
6. Clear SYSERR and CLKERR bits via MCR.
7. Set the appropriate bits in CKW to enable watchdogs.
5-7250aF
Figure 18. Programming Sequence
REPROGRAM PRIMARY
SELECTION:
CKR, CKM, CKP,
CKMD, CKRD
ENABLE OUTPUTS:
MCR = 0x0E
ENABLE WATCHDOGS:
CKW
≠
0x00
PROGRAM PRIMARY
SELECTION:
CKR, CKM, CKP,
CKMD, CKRD
DISABLE WATCHDOGS:
CKW = 0x00
CLEAR FALLBACK ERROR:
MCR = 0x6E
PROGRAM OTHER
REGISTERS
REPROGRAM SECONDARY
SELECTION: CKS,
IF REQUIRED
ENABLE WATCHDOGS:
CKW
≠
0x00
DISABLE WATCHDOGS:
CKW = 0x00
PROGRAM SECONDARY
SELECTION: CKS
PROGRAM OTHER
CLOCKS: CKN, CKND,
CK32, CK10
CONNECT
FALLBACK
YES, INTERRUPT
SERVICE ROUTINE
RETURN FROM
INTERRUPT
(IN
OPERATION)
NO