Data Sheet
June 2002
TMXF28155 Supermapper
155/51 Mbits/s SONET/SDH x28/x21 DS1/E1
103
Agere Systems Inc.
8 TMUX Registers
(continued)
Table 114. TMUX_RPOHMON[1—3][A—D], Receive Monitor Values (RO)
Address
Bit
Name
Function
Reset
Default
0x00
0x0
0x40027
15:11
10:8
RSVD
Reserved.
TMUX_RDIPMON1[2:0]
Receive Path RDI Monitor Value for Port 1.
See RDI-P
Detection Section on
page 385
.
TMUX_C2MON1[7:0]
Receive C2 Monitor Value for Port 1.
See Signal Label
C2 Byte Monitor Section on
page 384
.
TMUX_F2MON11[7:0]
Receive F2 Previous Monitor Value for Port 1.
See
Path User Byte F2 Monitor Section on
page 386
.
TMUX_F2MON01[7:0]
Receive F2 Current Monitor Value for Port 1.
See Path
User Byte F2 Monitor Section on
page 386
.
TMUX_F3MON11[7:0]
Receive F3 Previous Monitor Value for Port 1.
See
Path User Byte F3 Monitor Section on
page 386
.
TMUX_F3MON01[7:0]
Receive F3 Current Monitor Value for Port 1.
See Path
User Byte F3 Monitor Section on
page 386
.
TMUX_N1MON1[7:0]
Receive N1 Monitor Value for Port 1.
See N1 Byte Mon-
itor Section on
page 387
.
TMUX_K3MON1[7:0]
Receive K3 Monitor Value for Port 1.
See K3 Byte Mon-
itor Section on
page 387
.
RSVD
Reserved.
TMUX_RDIPMON2[2:0]
Receive Path RDI Monitor Value for Port 2.
See RDI-P
Detection Section on
page 385
.
TMUX_C2MON2[7:0]
Receive C2 Monitor Value for Port 2.
See Signal Label
C2 Byte Monitor Section on
page 384
.
TMUX_F2MON12[7:0]
Receive F2 Previous Monitor Value for Port 2.
See
Path User Byte F2 Monitor Section on
page 386
.
TMUX_F2MON02[7:0]
Receive F2 Current Monitor Value for Port 2.
See Path
User Byte F2 Monitor Section on
page 386
.
TMUX_F3MON12[7:0]
Receive F3 Previous Monitor Value for Port 2.
See
Path User Byte F3 Monitor Section on
page 386
.
TMUX_F3MON02[7:0]
Receive F3 Current Monitor Value for Port 2.
See Path
User Byte F3 Monitor Section on
page 386
.
TMUX_N1MON2[7:0]
Receive N1 Monitor Value for Port 2.
See N1 Byte Mon-
itor Section on
page 387
.
TMUX_K3MON2[7:0]
Receive K3 Monitor Value for Port 2.
See K3 Byte Mon-
itor Section on
page 387
.
RSVD
Reserved.
TMUX_RDIPMON3[2:0]
Receive Path RDI Monitor Value for Port 3.
See RDI-P
Detection Section on
page 385
.
TMUX_C2MON3[7:0]
Receive C2 Monitor Value for Port 3.
See Signal Label
C2 Byte Monitor Section on
page 384
.
TMUX_F2MON13[7:0]
Receive F2 Previous Monitor Value for Port 3.
See
Path User Byte F2 Monitor Section on
page 386
.
TMUX_F2MON03[7:0]
Receive F2 Current Monitor Value for Port 3.
See Path
User Byte F2 Monitor Section on
page 386
.
7:0
0x00
0x40028
15:8
0x00
7:0
0x00
0x40029
15:8
0x00
7:0
0x00
0x4002A
15:8
0x00
7:0
0x00
0x4002B
15:11
10:8
0x00
0x0
7:0
0x00
0x4002C
15:8
0x00
7:0
0x00
0x4002D
15:8
0x00
7:0
0x00
0x4002E
15:8
0x00
7:0
0x00
0x4002F
15:11
10:8
0x00
0x0
7:0
0x00
0x40030
15:8
0x00
7:0
0x00