T7630 Dual T1/E1 5.0 V Short-Haul Terminator (Terminator-II)
Alarms and Performance Monitoring
(continued)
Automatic and On-Demand Commands
Various alarms can be transmitted either automatically as a result of various alarm conditions or on demand. After
reset, all automatic transmissions are disabled. The user can enable the automatic or on-demand actions by set-
ting the proper bits in the automatic and on-demand action registers as identified below in Table 48. Table 48 shows
the programmable automatically transmitted signals and the triggering mechanisms for each. Table 49 shows the
on-demand commands.
Table 48. Automatic Enable Commands
Action
Trigger
Enabling Register Bit
FRM_PR27 bit 0 = 1
FRM_PR27 bit 1 = 1
Transmit Remote Frame Alarm
(RFA)
Loss of frame alignment (RLFA).
Loss of CEPT time slot 16 multiframe
alignment (RTS16LMFA).
Loss of CEPT time slot 0 multiframe
alignment (RTS0LMFA).
Detection of the timer (100 ms or
400 ms) expiration due to loss of
CEPT multiframe alignment.
Detection of the CEPT RSa6 = 8 (hex)
code.
Detection of the CEPT RSa6 = C (hex)
code.
Detection of CEPT CRC-4 error.
RTS0LMFA.
Detection of the timer (100 ms or
400 ms) expiration due to loss of
CEPT multiframe alignment.
RLFA.
Detection of the timer (100 ms or
400 ms) expiration due to loss of
CEPT multiframe alignment.
RTS16LMFA.
FRM_PR27 bit 2 = 1
FRM_PR27 bit 3 = 1
FRM_PR9 bit 7—bit 0 = 0xxxx1x1 or
0xxx1xx1
FRM_PR27 bit 4 = 1
FRM_PR27 bit 5 = 1
Transmit CEPT E Bit = 0
FRM_PR28 bit 3 = 1
FRM_PR28 bit 4 = 1
FRM_PR28 bit 5 = 1
FRM_PR9 bit 7—bit 0 = 0xxxx1x1 or
0xxx1xx1
FRM_PR19 bit 0 = 1
FRM_PR19 bit 1 = 1
FRM_PR9 bit 7—bit 0 = 0xxxx1x1 or
0xxx1xx1
FRM_PR41 bit 4 = 1
Transmit AIS to System
Transmit CEPT Time Slot 16
Remote Multiframe Alarm to
Line
Transmit CEPT AIS in Time Slot
16 to System
Automatic Enabling of DS1 Line
Loopback On/Off
Automatic Enabling of ESF FDL
Line Loopback On/Off
Automatic Enabling of ESF FDL
Payload Loopback On/Off
RTS16LMFA.
FRM_PR44 bit 6 = 1
Line loopback on/off code.
FRM_PR19 bit 4 =1
ESF line loopback on/off code.
FRM_PR19 bit 6 =1
ESF payload loopback on/off code.
FRM_PR19 bit 7 =1