Data Sheet
June 2002
TMXF28155 Supermapper
155/51 Mbits/s SONET/SDH x28/x21 DS1/E1
249
Agere Systems Inc.
12 28-Channel Framer Registers
(continued)
Table 318. FRM_FGR2, Framer Global Register 2 (R/W)
Table 319. FRM_FGR3, Framer Global Register 3 (R/W)
Table 320. FRM_FGR4, Framer Global Register 4 (COR)
Address
Bit
Name
Function
Reset
Default
0
0x80011
15
FRM_TC_EN
Terminal Count Enable.
0 = terminal count disabled use defaults.
1 = terminal count enabled.
Reserved.
Must write to 0.
14:8
7:0
RSVD
0000000
00011100
FRM_TC[7:0]
Terminal Count.
When enabled, the link counter will count
from 1 to the terminal count. The terminal count determines
the number of links available for use. The operational links are
link 1 to the link determined by the terminal count. By default,
the count is determined by the option bit, FRM_DS1_CEPTN
(
Table 313 on page 246
). In an application, where there is a
mix of DS1 and CEPT links or a small number of links, the ter-
minal count may be set by enabling FRM_TC_EN and setting
the terminal count, FRM_TC[7:0].
Note:
Minimum terminal count value is 4.
Address
Bit
Name
Function
Reset
Default
1
0x80012
15
FRM_TPSSE_IM
Transmit Path System Synchronization Error Inter-
rupt Mask.
A transmit path system synchronization error
interrupt is generated when synchronization is lost
between the receive system interface and the transmit
path line clock. FRM_TPSSE_IM is a global mask for the
interrupt status from each link. The individual link transmit
path system error interrupt status bits,
FRM_TPSSEI[28:1] are summarized in FRM_AR_IS bit
14 of FRM_SFGR3 (
Table 315 on page 248
).
0 = allows any synchronization error, as reported in the
synchronization status registers, to generate an inter-
rupt.
1 = masks any synchronization error, as reported in the
synchronization status registers, from generating an
interrupt.
Reserved.
Must write to 0.
14:0
RSVD
000000000
000000
Address
Bit
Name
Function
Reset
Default
00X0000
0x80014
15:0
FRM_TPSSEI[16:1]
Transmit Path System Synchronization Error Inter-
rupt.
1 = indicates a transmit path system synchronization
error on links 16 to 1.